Blocks the radiant heat by applying over 99% purity of Aluminum
Punching Polyethylene Foam : Blocks the radiant heat by maintaining half vacuum condition
HI-TECH Reflective Radiant Barrier is acknowledged by Korea government safety institute to make sure the product can be used in any place or environment.
We have received several Test Reports of the products to provide accurate product information to our customers.
PRODUCT DEMONSTRATION
Use LG raw material
which is harmless to human
body and guarantees non
detection of 4 major
heavy metals
Use flexible material to
work easily on corners
so excellently block the
flow of heat and cold air
Lightweight and easy
to cut which allows to
work on round building
with soft material
Reduce industrial wastes
and shortens the time of
insulating work compare
to the past.
Apply over 99% purity of Aluminum Foil to effectively block the radiant heat
Provide proper Reflective Radiant Barrier to each area with confidence by holding test reports for all product lines
TYPE |
Product Name |
Thickness |
Width |
Length |
Structure |
---|---|---|---|---|---|
SINGLE-SIDED |
HI-TECH 5000 |
5mm |
1m |
50M |
Silver/Copper PET + PE Foam |
HI-TECH 6000 |
6mm |
1m |
50M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ PE Foam |
|
HI-TECH 9000 |
9mm |
1m |
25M |
Silver/Copper Aluminum + PE Foam |
|
HI-TECH 7000 |
10mm |
1m |
25M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ PE Foam |
|
HI-TECH 8000 |
13mm |
1m |
25M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ PE Foam |
|
DOUBLE-SIDED |
HI-TECH 6000 |
6mm |
1m |
50M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ PE Foam + Silver PET |
HI-TECH 7000 |
10mm |
1m |
25M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ PE Foam + Silver PET |
|
HI-TECH 8000 |
13mm |
1m |
25M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ PE Foam + Silver PET |
|
HI-TECH 20T |
20mm |
1m |
20M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ Cross PE Foam + PE Foam + Silver PET |
|
HI-TECH 30T |
30mm |
1m |
15M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ Cross PE Foam + PE Foam + Cross PE Foam + |
|
HI-TECH 40T |
40mm |
1m |
10M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ Cross PE Foam + PE Foam + Cross PE Foam + |
|
HI-TECH 50T |
50mm |
1m |
8M |
Silver/Copper Aluminum + Long Fiber Nonwoven Fabric+ Cross PE Foam + PE Foam + Cross PE Foam + |
Emissivity is a measure of material’s radiating efficiency.
Theoretically, matter that absorbs the external energy and not reflect off regulates as 100% of emissivity.
Every factor has emissivity value between 0% ~ 100%, lower the value minimizes the absorption of radiant energy.
HI-Tech’s low emissivity and high
reflectivity blocks the cold outdoor air
and reflects warm indoor air which saves
the heating energy.
HI-Tech’s outstanding surface
reflectivity effectively prevents
building up the heat. It saves the
cooling energy so you can spend
pleasant summer all along.
HI-TECH Reflective Radiant Barrier resists over 90% of radiation movement.
Innovative insulation material minimizes energy loss to improve your environment quality.
Parts of the building |
Area |
||||
---|---|---|---|---|---|
Central district |
Southern district |
Jeju-do |
|||
External wall of living room |
When it directly contacts the outside air |
Apartment House |
Below 0.210 |
Below 0.260 |
Below 0.360 |
Other than |
Below 0.260 |
Below 0.320 |
Below 0.430 |
||
When it indirectly contacts the outside air |
Apartment House |
Below 0.300 |
Below 0.370 |
Below 0.520 |
|
Other than |
Below 0.360 |
Below 0.450 |
Below 0.620 |
||
Living room |
When it directly contacts the outside air |
Below 0.150 |
Below 0.180 |
Below 0.250 |
|
When it indirectly contacts the outside air |
Below 0.220 |
Below 0.260 |
Below 0.350 |
||
Living room floor of lowest floor |
When it directly contacts the outside air |
When it’s floor heating |
Below 0.180 |
Below 0.220 |
Below 0.290 |
When it’s not floor heating |
Below 0.220 |
Below 0.250 |
Below 0.330 |
||
When it indirectly contacts the outside air |
When it’s floor heating |
Below 0.260 |
Below 0.310 |
Below 0.410 |
|
When it’s not floor heating |
Below 0.300 |
Below 0.350 |
Below 0.470 |
||
Floor with heating system |
Below 0.810 |
Below 0.810 |
Below 0.810 |
||
Window and door |
When it directly contacts the outside air |
Apartment House |
Below 1.200 |
Below 1.400 |
Below 2.000 |
Other than Apartment House |
Below 1.500 |
Below 1.800 |
Below 2.400 |
||
When it indirectly contacts the outside air |
Apartment House |
Below 1.600 |
Below 1.800 |
Below 2.500 |
|
Other than Apartment House |
Below 1.900 |
Below 2.200 |
Below 3.000 |
1.중부지역 :서울특별시, 인천광역시, 경기도, 강원도(강릉시,동해시,속초시,삼척시,고성군,양양군 제외), 충청북도(영동군 제외), 충청남도(천안시), 경상북도(청송군)
2.남부지역 :부산광역시, 대구광역시, 광주광역시, 대전광역시, 울산광역시, 강원도(강릉시,동해시,속초시,삼척시,고성군,양양군), 충청북도(영동군), 충청남도(천안시 제외),
전라북도, 전라남도, 경상북도(청송군 제외), 경상남도, 세종특별자치시
Classification |
Thermal conductivity based on scale of thermal conductivity |
Insulations based on KS M 3808,3809 & KS L 9102 |
---|---|---|
가 |
Below 0.034(W/mk) |
Isopink (XPS) |
Styrofoam 2nd class 1~4 |
||
Hard Urethane |
||
Glass wool 48K, 64K, 80K, 96K, 120K |
||
Other insulation with below 0.034 W/mk of thermal conductivity |
||
나 |
Below 0.035-0.040(W/mk) |
Styrofoam 1st class 1~3 |
Mineral Fiber |
||
Glass wool 24K, 32K, 40K |
||
Other insulation with below 0.035-0.040 W/mk of thermal conductivity |
||
나 |
Below 0.041-0.046(W/mk) |
Styrofoam 1st class 4 |
Other insulation with below 0.041-0.046 W/mk of thermal conductivity |